7.5.4.10 Pset_BoilerTypeSteam

PSET_TYPEDRIVENOVERRIDE / IfcBoiler / STEAM

Boiler Type Steam: Steam boiler type common attributes.
: 蒸気ボイラタイプ共通属性

buildingSMART Data Dictionary

PSD-XML

NameTypeDescription
MaximumOutletPressure P_SINGLEVALUE / IfcLabel
Maximum Outlet PressureMaximum steam outlet pressure.
PressionSortieAdmissiblePression vapeur en sortie maximale
最大出口圧力最大出口蒸気圧力
NominalEfficiency P_TABLEVALUE / IfcThermodynamicTemperatureMeasure / IfcNormalisedRatioMeasure
Nominal EfficiencyThe nominal efficiency of the boiler as defined by the manufacturer. For steam boilers, a function of inlet temperature versus steam pressure. Note: as two variables are used, DefiningValues and DefinedValues are null, and values are stored in IfcTable in the following order: InletTemperature(IfcThermodynamicTemperatureMeasure) and OutletTemperature(IfcThermodynamicTemperatureMeasure) in DefiningValues, and NominalEfficiency(IfcNormalisedRatioMeasure) in DefinedValues. For example, DefininfValues(InletTemp, OutletTemp), DefinedValues(null, NominalEfficiency). The IfcTable is related to IfcPropertyTableValue using IfcMetric and IfcPropertyConstraintRelationship.
EfficacitéNominaleEfficacité nominale de la chaudière tel que définie par le constructeur. Pour les chaudières à vapeur, une fonction de la température en entrée par rapport à la pression de vapeur. Remarque: Comme deux variables sont utilisées ValeurDefinir et ValeursDefinies sont nulles, et les valeurs sont enregistrées dans IfcTable dans l'ordre suivant: - TempératureEntrée (IfcThermodynamicTemperatureMeasure) et TempératureSortie (IfcThermodynamicTemperatureMeasure) dans ValeursDefinir , et EfficacitéNominale (IfcNormalisedRatioMeasure) dansValeursDefinies. Par exemple, ValeursDefinir (TempératureEntrée, TempératureSortie), ValeursDefinies (nul, RendementNominal). IfcTable est lié à IfcPropertyTableValue qui utilise IfcMetric et IfcPropertyConstraintRelationship.
HeatOutput P_TABLEVALUE / IfcThermodynamicTemperatureMeasure / IfcEnergyMeasure
Heat OutputTotal nominal heat output as listed by the Boiler manufacturer. For steam boilers, it is a function of inlet temperature versus steam pressure. Note: as two variables are used, DefiningValues and DefinedValues are null, and values are stored in IfcTable in the following order: InletTemperature(IfcThermodynamicTemperatureMeasure) and OutletTemperature(IfcThermodynamicTemperatureMeasure) in DefiningValues, and HeatOutput(IfcEnergyMeasure) in DefinedValues. For example, DefiningValues(InletTemp, OutletTemp), DefinedValues(null, HeatOutput). The IfcTable is related to IfcPropertyTableValue using IfcMetric and IfcPropertyConstraintRelationship.
RendementChaleurRendement total nominal tel que défini par le constructeur de chaudière. Pour les chaudières à vapeur, une fonction de la température en entrée par rapport à la pression de vapeur. Remarque: Comme deux variables sont utilisées ValeurDefinir et ValeursDefinies sont nulles, et les valeurs sont enregistrées dans IfcTable dans l'ordre suivant: - TempératureEntrée (IfcThermodynamicTemperatureMeasure) et TempératureSortie (IfcThermodynamicTemperatureMeasure) dans ValeursDefinir , et Rendement de chaleur (IfcEnergyMeasure) dansValeursDefinies. Par exemple, ValeursDefinir (TempératureEntrée, TempératureSortie), ValeursDefinies (nul, RendementChaleur). IfcPropertyTable est lié à IfcMetric qui utilise IfcMetric et IfcPropertyConstraintRelationship.