7.6.4.20 Pset_WasteTerminalTypeFloorWaste

PSET_TYPEDRIVENOVERRIDE / IfcWasteTerminal / FLOORWASTE

Waste Terminal Type Floor Waste: Pipe fitting, set into the floor, that collects waste water and discharges it to a separate trap.
: 廃水や廃水を集めて分離する防臭弁を持つ、床に据え付けられた配管。

buildingSMART Data Dictionary

PSD-XML

NameTypeDescription
NominalBodyLength P_SINGLEVALUE / IfcPositiveLengthMeasure
Nominal Body LengthNominal or quoted length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the waste.
呼称躯体長廃棄物の区画の半径か局所座標系のX軸に沿って測定された呼称もしくは積算された長さ。
NominalBodyWidth P_SINGLEVALUE / IfcPositiveLengthMeasure
Nominal Body WidthNominal or quoted length measured along the y-axis in the local coordinate system of the waste.
呼称躯体幅廃棄物の半径か局所座標系のY軸に沿って測定された呼称もしくは積算された長さ。
NominalBodyDepth P_SINGLEVALUE / IfcPositiveLengthMeasure
Nominal Body DepthNominal or quoted length measured along the z-axis in the local coordinate system of the waste.
呼称躯体深さ廃棄物の半径か局所座標系のZ軸に沿って測定された呼称もしくは積算された長さ。
OutletConnectionSize P_SINGLEVALUE / IfcPositiveLengthMeasure
Outlet Connection SizeSize of the outlet connection from the object.
排気口サイズ要素からの排気口サイズ。
CoverLength P_SINGLEVALUE / IfcPositiveLengthMeasure
Cover LengthThe length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the waste.
カバー長さ局所座標系のX軸に沿うか、半径(円状の形の場合)で測定された防臭弁カバーの長さ。
CoverWidth P_SINGLEVALUE / IfcPositiveLengthMeasure
Cover WidthThe length measured along the y-axis in the local coordinate system of the cover of the waste.
カバー幅局所座標系のY軸で測定された防臭弁カバーの長さ。

Link to this page  Link to this page